24 / 7 Emergency Service Available. Call Us Now: 1.844.894.6832

Durham Region Air Conditioning Repair, Service and Installation

CLICK HERE FOR A FREE QUOTATION

If you're looking for help fixing your Ducane Air Conditioner, look no further! Our comprehensive Ducane Air Conditioner repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model's error codes.


CODE: POWER (Green).
RESULT: Module has power
FIX: Supply voltage is present at module terminals.

CODE: TRIP (Red).
RESULT: Thermostat demand signal Y1 is present, but the compressor is not running
FIX: 1. Compressor protector is open - Check for high head pressure - Check compressor supply voltage 2. Outdoor unit power disconnect is open 3. Compressor circuit breaker or fuse(s) is open 4. Broken wire or connector is not making contact 5. Low pressure switch open if present in system 6. Compressor contactor has failed open.

CODE: ALERT (Yellow) Flash Code 1.
RESULT: Long Run Time Compressor is running extremely long run cycles
FIX: n/a.

CODE: ALERT (Yellow) Flash Code 2.
RESULT: System Pressure Trip Discharge or suction pressure out of limits or compressor overloaded
FIX: 1. High head pressure - Check high pressure switch if present in system - Check if system is overcharged with refrigerant - Check for non-condensable in system 2. Condenser coil poor air circulation (dirty, blocked, damaged) 3. Condenser fan is not running - Check fan capacitor - Check fan wiring and connectors - Check fan motor for failure or blockage 4. Return air duct has substantial leakage 5. If low pressure switch present in system, check Flash Code 1 information.

CODE: ALERT (Yellow) Flash Code 3.
RESULT: Short Cycling Compressor is running only briefly
FIX: 1. Thermostat demand signal is intermittent 2. Time delay relay or control board defective 3. If high pressure switch present, go to Flash Code 2 information 4. If low pressure switch present, go to Flash Code 1 information.

CODE: ALERT (Yellow) Flash Code 4.
RESULT: Locked Rotor
FIX: 1. Run capacitor has failed 2. Low line voltage (contact utility if voltage at disconnect is low) - Check wiring connections 3. Excessive liquid refrigerant in compressor 4. Compressor bearing are seized 5. Measure compressor oil level.

CODE: ALERT (Yellow) Flash Code 5.
RESULT: Open Circuit
FIX: 1. Outdoor unit power disconnect is open 2. Compressor circuit breaker or fuse(s) is open 3. Compressor contactor has failed open - Check compressor contactor wiring and connectors - Check for compressor contactor failure (burned, pitted, or open) - Check wiring and connectors between supply and compressor - Check for low pilot voltage at compressor contactor coil 4. High pressure switch is open and requires manual reset 5. Open circuit in compressor supply wiring or connections 6. Unusually long compressor protector reset time due to extreme ambient temperature 7. Compressor windings are damaged - Check compressor motor winding resistance.

CODE: ALERT (Yellow) Flash Code 6.
RESULT: Open Start Circuit. Current only in run circuit
FIX: 1. Run capacitor has failed 2. Open circuit in compressor start wiring or connections - Check wiring and connectors between supply and the compressor S terminal 3. Compressor start winding is damaged - Check compressor motor winding resistance.

CODE: ALERT (Yellow) Flash Code 7.
RESULT: Open Run Circuit. Current only in start circuit.
FIX: 1. Open circuit in compressor run wiring or connections - Check wiring and connectors between supply and the compressor R terminal 2. Compressor run winding is damaged - Check compressor motor winding resistance.

CODE: ALERT (Yellow) Flash Code 8.
RESULT: Welded Contactor. Compressor always runs
FIX: 1. Compressor contactor has failed closed 2. Thermostat demand signal not connected to module.

CODE: ALERT (Yellow) Flash Code 9.
RESULT: Low Voltage. Control circuit less than 17VAC
FIX: 1. Control circuit transformer is overloaded 2. Low line voltage (contact utility if voltage at disconnect is low) - Check wiring conditions.


See What Our Customers Are Saying:

by Private User on Twintech Heating and Cooling

Flawless transaction. They did exactly what they promised, showed-up on time, cleaned-up, and were highly professional. Highly recommended.

by Bill Edmondson on Twintech Heating and Cooling

Salesperson and 2 man installation team were all professional and
knew their stuff. All three were friendly and helpful, answering all
my questions. The quality of their work demonstrated their experience
and expertise in their field.

by Private User on Twintech Heating and Cooling

A dear late cousin of mine recommended this company and I have been happy with the service.

by Private User on Twintech Heating and Cooling

We are very pleased with the work done by Twintech. They were very professional from start to finish. Dave came to our home and gave us a very competitive quote for new high efficiency furnace and air conditioner. The installers were very courteous and professional. We would highly recommend them.

by W1n5t0n1987! on Twintech Heating and Cooling

Great experience getting an old furnace replaced.
Sales Guy (Dave) was great - honest, responsive, and friendly.
The work itself was done quickly and we are very happy with the outcome, thank you! We recommend TwinTech!

by Private User on Twintech Heating and Cooling

This review is late coming so my apologies to the amazing Twin Tech team! I contacted Dave at Twin Tech for a quote this past Feb (as I was collecting a few) and his recommendation was excellent. From the first meeting with Dave to the team installing the new furnace, not once did i feel uncomfortable . The team were extremely professional yet personable and clean and tidy. Decent companies still exist!
The new furnace just purrs and its just amazing the difference it has made!
(PS my sibling ended up getting a furnace from them as well)

by Private User on Twintech Heating and Cooling

The service was Twintech was excellent.
Dave our salesperson was easy to talk to and was professional. The unit recommended meets our needs and budget.
Greg and his team arrived on time for the installation and even got rid of the garbage the contractors left in our furnace.
Would definitely recommend Twintech.

by Steve V, Toronto on Twintech Heating and Cooling

Our old water tank was installed in 1997. Wasn't working as well as it should so we looked into a tankless as it is more efficient and a space saver! we had used Twintech in the past for a furnace cleaning and were satisfied with that so we decided to ask for a quote for the changeover. Gary arrived and provided the options and the quote fit within our budget so we decide to go with them after receiving a few alternative quotes from other companies. They did what the said would be done and it was completed within a reasonable time frame! Removal and cleanup of the old tank was seamless. We are now enjoying consistent and efficient Hot water! I recommend Twintech and would use them for future projects!

by New AC Unit + Humidifier on Twintech Heating and Cooling

One of the most honest HVAC companies out there! Dave was very helpful and informative in helping us choose a new AC unit. While they weren’t the lowest quote, we went with them because we trusted Dave and he was the most honest guy out of the companies that quoted us.
Greg and his crew who installed the unit were very professional and did a great job. If I could do it over again I would choose Twintech again.

by Private User on Twintech Heating and Cooling

Relocated and replaced our air conditioning unit. Fast, professional, and high quality service. We would definitely use them again for future projects!