The flashing LEDs on your furnace will correspond to a specific fault code that is shown here on their diagnostic chart.


Founded in 1874, YORK has been an industry leader since the beginning. A revolutionary YORK "air washing" system installed in 1914 was the precursor to modern-day air conditioning. In 1924, the world's first air-conditioned office building used YORK equipment. And today, YORK products are heating and cooling iconic structures, including the Empire State Building, the English Chunnel, the U.S. Capitol Building and the Sydney Opera House.


York Furnace error codes are seen in three colors, red, green, and amber/yellow. Each color will also flash a specific number of times to signify a specific error. Breaking down each color, and number of flashes, will help you solve the problem you are having with your York Furnace.


CODE: SLOW GREEN FLASH
RESULT: Normal operation

CODE: SLOW AMBER FLASH
RESULT: Normal operation with call for heat

CODE: RAPID RED FLASH
RESULT: Twinning error, incorrect 24V phasing.
FIX: Check twinning wiring. Flame sense current is below 1.5 microamps

CODE: RAPID AMBER FLASH
RESULT: Check and clean flame sensor. Check for proper gas flow. Verify that current is greater than 1.5 microamps at flame current test pad.

CODE: 4 AMBER FLASHES
RESULT: The control is receiving a "Y" signal from the thermostat without a "G" signal, indicating improper thermostat wiring.

CODE: 1 RED FLASH
RESULT: This indicates that flame was sensed when there was not a call for heat.
FIX: The control will turn on both the inducer motor and supply air blower. A gas valve that leaks or is slow closing would typically cause this fault.

CODE: 2 RED FLASHES
RESULT: This indicates that the normally open pressure switch contacts are stuck in the closed position.
FIX: The control confirms these contacts are open at the beginning of each heat cycle. This would indicate a faulty pressure switch or miswiring. This indicates the normally open pressure switch contact did not close after the inducer was energized.

CODE: 3 RED FLASHES
RESULT: This could be caused by a number of problems: faulty inducer, blocked vent pipe broken pressure switch hose or faulty pressure switch.

CODE: 4 RED FLASHES
RESULT: This indicates that the main limit switch has opened its normally closed contacts.
FIX: The control will operate the supply air blower and inducer. This condition may be caused by: dirty filter, improperly sized duct system, incorrect blower speed setting, incorrect firing rate or faulty blower motor. Also, this fault code could be caused by a blown fuse located on the control board.

CODE: 5 RED FLASHES
RESULT: This fault is indicated if the normally closed contacts in the rollout switch opens.
FIX: The rollout control is manually reset. If it has opened, check for proper combustion air, proper inducer operation, and primary heat exchanger failure or burner problem. Be sure to reset the switch and cycle power (24 VAC) to the control after correcting the failure condition. Also, this fault code could be caused by a blown fuse located on the control board.

CODE: 6 RED FLASHES
RESULT: This indicates that after the unit was operating, the pressure switch opened 4 times during the call for heat.
FIX: If the main blower is in a "Delay on" mode, it will complete it, and any subsequent delay off period. The furnace will lock out for one hour and then restart.

CODE: 7 RED FLASHES
RESULT: This fault code indicates that the flame could not be established. This no-light condition occurred 3 times (2 retries) during the call for heat before locking out.
FIX: Low gas pressure, faulty gas valve, dirty or faulty flame sensor, faulty hot surface ignitor or burner problem may cause this. The furnace will lock out for one hour and then restart.

CODE: 8 RED FLASHES
RESULT: This fault is indicated if the flame is lost 5 times (4 recycles) during the heating cycle.
FIX: This could be caused by low gas pressure, dirty or faulty flame sensor or faulty gas valve. The furnace will lock out for one hour and then restart.

CODE: 9 RED FLASHES
RESULT: Indicates reversed line voltage polarity or grounding problem.
FIX: Both heating and cooling operations will be affected. check polarity at furnace and branch. Check furnace grounding. Check that flame probe is not shorted to chassis.

CODE: 10 RED FLASHES
RESULT: Flame sensed with no call for heat.
FIX: Check gas valve and gas valve wiring This indicates that a primary or auxiliary limit switch has opened its normally-closed contacts and has remained open for more than five minutes.

CODE: 11 RED FLASHES
RESULT: This condition is usually caused by a failed blower motor or blower wheel.
FIX: Cycle power (24 VAC) to the control to reset the hard lockout condition after correcting the failure condition.

CODE: 12 RED FLASHES
RESULT: This code indicates an open igniter circuit.
FIX: This could be a disconnected or loose wire or a cracked or broken igniter.

CODE: STEADY ON RED
RESULT: Control failure.
FIX: Replace control board.

CODE: 60-MINUTE AUTOMATIC RESET FROM LOCKOUT
RESULT: This control includes a "watchdog" type circuit that will reset from a lockout condition after 60 minutes. Operational faults 6, 7, 8 will be reset. This provides protection to an unoccupied structure if a temporary condition exists causing a furnace malfunction. An example would be a low incoming gas supply pressure preventing unit operation When the gas pressure is restored, at some point the "watchdog" would restart the unit and provide heat for the house.

CODE: IGNITION CONTROL FLAME SENSE LEVELS
RESULT: Normal flame sense current is approximately 3.7 microamps DC Low flame signal warning starts at 1.5 microamps. Low flame signal control lockout point is 0.1 microamps DC.


See What Our Customers Are Saying:

by Private User from Kitchener on Twintech Heating and Cooling

Twintech were fast and efficient contractors. It only took 48 hours between an initial home visit and complete installation. The workmen were polite and hardworking. The site was left clean with the old furnace etc. removed. They helped arrange an environmental assessment in order that I could receive the maximum rebate. They even called me within a week to determine if I was satisfied with their work and to reassure me that I could call them anytime I experienced heating difficulties or had any questions. I recommend Twintech for your heating problems.

by dlcarroll in Vaughan on Twintech Heating and Cooling

Courteous and professional service from initial consultation through to the installation. We highly recommend Twintech for outstanding service in the industry. Competitive pricing, professional and accurate advice, attention to detail, respect for their client's home and cleaning up at the completion of installation.

by TraceyG from Toronto on Twintech Heating and Cooling

Last night was the coldest day of the year so far and I woke up to my house being 54 degrees... I called Twintech at 2:45am and Greg was on site by 3:30am. The furnace required a part and he returned to his shop and came back to my home around 4:15am, furnace up and running by 4:30am. THANK YOU TWINTECH! Your service is second to none.

by Cristelle from Ajax on Twintech Heating and Cooling

After much research & getting 4 quotes, we hired Twintech team for our new furnace installation, prices were fair, they carried great product brands & more importantly installation was expertly done by one of the owners (Greg & his assistant Peter) which gave me an added piece of mind. Dave was very organized & answered all my questions in great detail, especially re: the Enbridge & Govt. rebate program.

by David from Pickering on Twintech Heating and Cooling

My old air conditioner was 20 years old and developed a Freon leak and it was more cost effective to replace rather than repair. There are a large number of heating and air conditioning companies available in my area so I contacted several for quotes. Twintech heating and cooling responded quickly to the inquiry I left on their website and their sales person Dave came by the following day. He was knowledgeable about the field and was able to show copies of the various refrigeration and gas fitting licenses along with workmens compensation, TSSA and other certifications. He also suggested a particular manufacturer and model of AC unit appropriate to my house and gave me a quote. Since the price was reasonable, service had been good and the reviews on the internet were also good, I decided to purchase an AC unit from them. Installation was quickly scheduled. They showed up on time, did a good job installing the new unit including some sheet metal work to get the new heat exchanger to fit in the furnace duct, and cleaned up afterward. In addition, they noticed that my existing AC was installed too close to the furnace exhaust (based on building code) and were able to mount the new AC the appropriate distance from the exhaust. Overall, they did an excellent job and were a pleasure to work with.

by LP from Pickering on Twintech Heating and Cooling

All interactions from sales to installation were Courteous and professional. The installation was seamless and the attention to detail including clean up was outstanding. I highly recommend TwinTech Heating and Cooling.

by David in Pickering on Twintech Heating and Cooling

Twintech's Salesman Dave arrived promptly was friendly and courteous, listened and assured us the installation would be completed according to our requests. The crew arrived early morning on May 11th, 2018 and worked through till late afternoon non-stop. They were very friendly, very professional, their expertise was excellent, their workmanship outstanding and the installation was completed in a timely and efficient manner. We were completely satisfied and happy with the quality of the work.

by Jennifer in Toronto on Twintech Heating and Cooling

I had cold and hot spots all over my 70 yr old home. My furnace is quite new and Greg optimized the fan and furnace. The original installer just took it out of the box with factory settings and installed it- basically running at 50% of capacity. Greg also routed heat into my laundry room, yeah - so now I can renovate laundry room - thanks Greg. He is honest, professional and knowledgeable. I will be calling him back in the spring to optimize my AC as well.

by Happy Homeowner in Toronto on Twintech Heating and Cooling

Wonderful from beginning to end. I tend to fret and worry about home improvements but the excellent team at TwinTech put my mind as ease. They listen, they are patient and best of all ... the work they did is amazing! I chose the Goodman 80K BTU 2 stage furnace and the matching Goodman air conditioner. Greg, Grant and Poitr "Peter" arrived on time, took great care, explained everything to me and they answered all of my questions. They carefully adjusted the factory settings to optimize the furnace for my house and they also checked the duct work in the basement. Dave, the Sales Manager, came by to say "hello" and to see if I was happy. YES, I am happy with the work! The furnace is very quiet. I have it running on low just to circulate the air in the house and it's so much quieter than my old furnace. When I need new duct work for an upcoming basement renovation TwinTech will be my first choice. I highly recommend TwinTech. PS. They were even nice to my dogs.

by Les G. from Pickering on Twintech Heating and Cooling

Greg was prompt on the scheduled day of installation and the work was done well within the time estimated beforehand. Installation was neat and the equipment and scope of work was as specified in the quote. One item I must point out is that we were faced with a "No Heat" situation the day before the scheduled installation and Greg came out to address it free of charge. Not only that, but he also corrected an installation fault with our smart thermostat that was not part of the original job, again free of charge.