CODE: E0.
RESULT: Indoor EEPROM (Electrically Erasable Programmable Read-Only Memory) error.

CODE: E1.
RESULT: Indoor and outdoor unit communication malfunction.

CODE: E3.
RESULT: Indoor fan speed malfunction.

CODE: E4.
RESULT: Indoor room temperature sensor error.

CODE: E5.
RESULT: Evaporator coil temperature sensor error.

CODE: EC.
RESULT: Refrigerant leak detection system malfunction.

CODE: EE.
RESULT: Water level alarm malfunction.

CODE: E8.
RESULT: Dual indoor unit (twin model only) communication malfunction.

CODE: E9.
RESULT: Other twin model malfunction.

CODE: F0.
RESULT: Overload protection.

CODE: F1.
RESULT: Outdoor temperature sensor error.

CODE: F2.
RESULT: Outdoor condenser pipe sensor error.

CODE: F3.
RESULT: Discharge air temperature sensor error.

CODE: F4.
RESULT: Outdoor EEPROM (Electrically Erasable Programmable Read-Only Memory) error.

CODE: F5.
RESULT: Outdoor fan speed (DC fan motor only) malfunction.

CODE: F6.
RESULT: T2b sensor error.

CODE: F7.
RESULT: Auto-lifting panel communication error.

CODE: F8.
RESULT: Auto-lifting panel malfunction.

CODE: F9.
RESULT: Auto-lifting panel is open.

CODE: P0.
RESULT: Inverter module IPM protection.

CODE: P1.
RESULT: High/Low voltage protection.

CODE: P2.
RESULT: Compressor top overheating protection.

CODE: P3.
RESULT: Outdoor low temperature protection.

CODE: P4.
RESULT: Compressor drive error.

CODE: P5.
RESULT: Mode conflict.

CODE: P6.
RESULT: Compressor low-pressure protection.

CODE: P7.
RESULT: Outdoor IGBT sensor error.

Luxaire Central Controller Fault Codes.

CODE: H3.
RESULT: Outdoor adding malfunction (valid for host unit).

CODE: H2.
RESULT: Outdoor decreasing malfunction (valid for host unit).

CODE: H1.
RESULT: Net communication malfunction.

CODE: EF.
RESULT: Other malfunction.

CODE: E4-T4.
RESULT: Temp. Sensor malfunction.

CODE: E3-T3.
RESULT: Temp. Sensor malfunction.

CODE: E2.
RESULT: Sensor malfunction.

CODE: E1-E0.
RESULT: Communication malfunction Phase sequence or lack of phase.

CODE: PF.
RESULT: Other Protection.

CODE: PE.
RESULT: Oil Balance.

CODE: PD.
RESULT: Oil Return.

CODE: PA.
RESULT: Defrost Protection.

CODE: P8.
RESULT: Compressor Current 3rd Protection.

CODE: P7.
RESULT: Compressor Current 2nd Protection.

CODE: P5.
RESULT: Condenser High Temp. Protection.

CODE: P4.
RESULT: Discharge Pipe Temp. Protection.

CODE: P3.
RESULT: Compressor Current 1st Protection.

CODE: P2.
RESULT: Discharge Low- pressure Protection.

CODE: P1-P0.
RESULT: Discharge High- pressure Protection Compressor High Temp. Protection.

Malfunction Code of Outdoor unit.

CODE: E1.
RESULT: Phase sequence error.

CODE: E2.
RESULT: Communication malfunction between indoor/outdoor units.

CODE: E3.
RESULT: T3 temperature sensor malfunction.

CODE: E4.
RESULT: T4 temperature sensor malfunction.

CODE: E5.
RESULT: T5 temperature sensor malfunction.

CODE: E6.
RESULT: Water-level alarm malfunction.

Luxaire Central Air Conditioning Error Codes,

CODE: EF.
RESULT: Other malfunction PF Other Protection.

CODE: EE.
RESULT: Water level checking malfunction PE Reserve.

CODE: ED.
RESULT: Outdoor protection PD Reserve.

CODE: EC.
RESULT: Clear malfunction PC Reserve.

CODE: EB.
RESULT: Inverter Module Protection PB Reserve.

CODE: EA.
RESULT: Compressor Over-current (4 times) PA Reserve.

CODE: E9.
RESULT: Communication malfunction between PCB and Display board P9 Reserve.

CODE: E8.
RESULT: Fan motor checking out of control P8 Compressor Over-current.

CODE: E7.
RESULT: EEPROM malfunction P7 Power Lack/Over Volt Protection.

CODE: E6.
RESULT: Over-zero checking malfunction P6 Discharge Low-pressure Protection.

CODE: E5.
RESULT: T3 sensor malfunction P5 Discharge High-pressure Protection.

CODE: E4.
RESULT: T2B sensor malfunction P4 Discharge Pipe Temp. Protection.

CODE: E3.
RESULT: T2A sensor malfunction P3 Compressor Temp. Protection.

CODE: E2.
RESULT: T1 sensor malfunction P2 Condenser High Temp. Protection.

CODE: E1.
RESULT: Communication malfunction P1 Anti-cooling or Defrost Protection.

CODE: E0.
RESULT: Phase sequence or lack of phase P0 Evaporator Temp. Protection.

CODE: 03#.
RESULT: CCM/PC(gateway) Communication Malfunction.

CODE: 02#.
RESULT: CCM/Function Module Communication Malfunction.

CODE: 01#.
RESULT: CCM/NIM Communication Malfunction.

CODE: 00#.
RESULT: CCM/PCB Communication Malfunction.

Luxaire Wall Mounted Type Ac Error Codes.

CODE: E7.
RESULT: Communication fault between indoor and outdoor units.

CODE: E1.
RESULT: Room temperature sensor failure.

CODE: E4.
RESULT: Indoor EEPROM error.

CODE: E14.
RESULT: Indoor fan motor malfunction.

CODE: F12.
RESULT: Outdoor EEPROM error.

CODE: F1.
RESULT: The protection of IPM.

CODE: F22.
RESULT: Overcurrent protection of AC electricity for the outdoor model.

CODE: F3.
RESULT: Communication fault between the IPM and outdoor PCB.

CODE: F19.
RESULT: Power voltage is too high or low.

CODE: F4.
RESULT: Overheat protection for Discharge temperature.

CODE: F8.
RESULT: Outdoor DC fan motor fault.

CODE: F21.
RESULT: Defrost temperature sensor failure.

CODE: F7.
RESULT: Suction temperature sensor failure.

CODE: F6.
RESULT: Ambient temperature sensor failure.

CODE: F25.
RESULT: Discharge temperature sensor failure.

CODE: F11.
RESULT: deviate from the normal for the compressor.

CODE: F28.
RESULT: Loop of the station detect error.

CODE: F2.
RESULT: Overcurrent of the compressor.

CODE: F23.
RESULT: Overcurrent protection for single-phase of the compressor.


See What Our Customers Are Saying:

by Private User from Kitchener on Twintech Heating and Cooling

Twintech were fast and efficient contractors. It only took 48 hours between an initial home visit and complete installation. The workmen were polite and hardworking. The site was left clean with the old furnace etc. removed. They helped arrange an environmental assessment in order that I could receive the maximum rebate. They even called me within a week to determine if I was satisfied with their work and to reassure me that I could call them anytime I experienced heating difficulties or had any questions. I recommend Twintech for your heating problems.

by dlcarroll in Vaughan on Twintech Heating and Cooling

Courteous and professional service from initial consultation through to the installation. We highly recommend Twintech for outstanding service in the industry. Competitive pricing, professional and accurate advice, attention to detail, respect for their client's home and cleaning up at the completion of installation.

by TraceyG from Toronto on Twintech Heating and Cooling

Last night was the coldest day of the year so far and I woke up to my house being 54 degrees... I called Twintech at 2:45am and Greg was on site by 3:30am. The furnace required a part and he returned to his shop and came back to my home around 4:15am, furnace up and running by 4:30am. THANK YOU TWINTECH! Your service is second to none.

by Cristelle from Ajax on Twintech Heating and Cooling

After much research & getting 4 quotes, we hired Twintech team for our new furnace installation, prices were fair, they carried great product brands & more importantly installation was expertly done by one of the owners (Greg & his assistant Peter) which gave me an added piece of mind. Dave was very organized & answered all my questions in great detail, especially re: the Enbridge & Govt. rebate program.

by David from Pickering on Twintech Heating and Cooling

My old air conditioner was 20 years old and developed a Freon leak and it was more cost effective to replace rather than repair. There are a large number of heating and air conditioning companies available in my area so I contacted several for quotes. Twintech heating and cooling responded quickly to the inquiry I left on their website and their sales person Dave came by the following day. He was knowledgeable about the field and was able to show copies of the various refrigeration and gas fitting licenses along with workmens compensation, TSSA and other certifications. He also suggested a particular manufacturer and model of AC unit appropriate to my house and gave me a quote. Since the price was reasonable, service had been good and the reviews on the internet were also good, I decided to purchase an AC unit from them. Installation was quickly scheduled. They showed up on time, did a good job installing the new unit including some sheet metal work to get the new heat exchanger to fit in the furnace duct, and cleaned up afterward. In addition, they noticed that my existing AC was installed too close to the furnace exhaust (based on building code) and were able to mount the new AC the appropriate distance from the exhaust. Overall, they did an excellent job and were a pleasure to work with.

by LP from Pickering on Twintech Heating and Cooling

All interactions from sales to installation were Courteous and professional. The installation was seamless and the attention to detail including clean up was outstanding. I highly recommend TwinTech Heating and Cooling.

by David in Pickering on Twintech Heating and Cooling

Twintech's Salesman Dave arrived promptly was friendly and courteous, listened and assured us the installation would be completed according to our requests. The crew arrived early morning on May 11th, 2018 and worked through till late afternoon non-stop. They were very friendly, very professional, their expertise was excellent, their workmanship outstanding and the installation was completed in a timely and efficient manner. We were completely satisfied and happy with the quality of the work.

by Jennifer in Toronto on Twintech Heating and Cooling

I had cold and hot spots all over my 70 yr old home. My furnace is quite new and Greg optimized the fan and furnace. The original installer just took it out of the box with factory settings and installed it- basically running at 50% of capacity. Greg also routed heat into my laundry room, yeah - so now I can renovate laundry room - thanks Greg. He is honest, professional and knowledgeable. I will be calling him back in the spring to optimize my AC as well.

by Happy Homeowner in Toronto on Twintech Heating and Cooling

Wonderful from beginning to end. I tend to fret and worry about home improvements but the excellent team at TwinTech put my mind as ease. They listen, they are patient and best of all ... the work they did is amazing! I chose the Goodman 80K BTU 2 stage furnace and the matching Goodman air conditioner. Greg, Grant and Poitr "Peter" arrived on time, took great care, explained everything to me and they answered all of my questions. They carefully adjusted the factory settings to optimize the furnace for my house and they also checked the duct work in the basement. Dave, the Sales Manager, came by to say "hello" and to see if I was happy. YES, I am happy with the work! The furnace is very quiet. I have it running on low just to circulate the air in the house and it's so much quieter than my old furnace. When I need new duct work for an upcoming basement renovation TwinTech will be my first choice. I highly recommend TwinTech. PS. They were even nice to my dogs.

by Les G. from Pickering on Twintech Heating and Cooling

Greg was prompt on the scheduled day of installation and the work was done well within the time estimated beforehand. Installation was neat and the equipment and scope of work was as specified in the quote. One item I must point out is that we were faced with a "No Heat" situation the day before the scheduled installation and Greg came out to address it free of charge. Not only that, but he also corrected an installation fault with our smart thermostat that was not part of the original job, again free of charge.