napoleon air conditioner error codes

24 / 7 Emergency Service Available. Call Us Now: 1.844.894.6832

Durham Region Air Conditioning Repair, Service and Installation

napoleon air conditioner error codes
CLICK HERE FOR A FREE QUOTATION

napoleon air conditioner codes

If you're looking for help fixing your napoleon air conditioner, look no further! Our comprehensive napoleon air conditioner repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model's error codes.


PROBLEM: Unit will not operate,
RESULT: Power disconnected or loose connection.
FIX: Check power supply to unit. Check voltage at contactor.

PROBLEM: Unit will not operate,
RESULT: Blown fuse / breaker tripped.
FIX: Replace fuses/reset breaker.

PROBLEM: Unit will not operate,
RESULT: Thermostat out of calibration is set too high.
FIX: Reset.

PROBLEM: Unit will not operate,
RESULT: Contactor defective.
FIX: Check for 24VAC at contactor coil - replace if open.

PROBLEM: Unit will not operate,
RESULT: Transformer defective.
FIX: Check wiring - replace transformer.

PROBLEM: Unit will not operate,
RESULT: High pressure control open (if provided).
FIX: Reset - see high pressure connection.

PROBLEM: Outdoor fan on; Compressor off.
RESULT: Run or start capacitor defective.
FIX: Replace.

PROBLEM: Outdoor fan on; Compressor off.
RESULT: Start relay defective.
FIX: Replace.

PROBLEM: Outdoor fan on; Compressor off.
RESULT: Loose wire.
FIX: Check for correct voltage at compressor - check and tighten all connections.

PROBLEM: Outdoor fan on; Compressor off.
RESULT: Compressor stuck, grounded or open motor winding, open internal overload.
FIX: Wait at least 2 hours for overload to reset; if still open, replace the compressor.

PROBLEM: Too little cooling.
RESULT: Low voltage condition.
FIX: Add start kit components.

PROBLEM: Too little cooling.
RESULT: Improperly sized unit.
FIX: Recalculate load.

PROBLEM: Too little cooling.
RESULT: Improper indoor airflow.
FIX: Check-should be approximately 400 CFM per ton.

PROBLEM: Too little cooling.
RESULT: Incorrect refrigerant charge.
FIX: Charge per procedure in installation manual.

PROBLEM: Too little cooling.
RESULT: Air, non-condensables or moisture in system.
FIX: Recover refrigerant.

PROBLEM: Compressor operates in short cycles.
RESULT: Incorrect voltage.
FIX: At compressor terminals, voltage must be +/10% of nameplate marking when unit is operating.

PROBLEM: Compressor operates in short cycles.
RESULT: Defective overload protector.
FIX: Replace - check for correct voltage.

PROBLEM: Compressor operates in short cycles.
RESULT: Refrigerant undercharge.
FIX: Add refrigerant.

PROBLEM: High head pressure; Low suction pressure.
RESULT: Restriction in liquid line, expansion device or filter drier.
FIX: Remove or replace defective component.

PROBLEM: High head pressure; Low suction pressure.
RESULT: Lack of sufficient indoor airflow.
FIX: Clean/check filters, registers, or evaporator coil that may cause a restriction.

PROBLEM: High head pressure; Normal suction pressure.
RESULT: Dirty outdoor coil.
FIX: Clean coil.

PROBLEM: High head pressure; Normal suction pressure.
RESULT: Refrigerant overcharge.
FIX: Correct system charge.

PROBLEM: High head pressure; Normal suction pressure.
RESULT: Outdoor fan not running.
FIX: Repair or replace.

PROBLEM: High head pressure; Normal suction pressure.
RESULT: Air or non-condensables in system.
FIX: Recover refrigerant, evacuate and recharge.

PROBLEM: Low head pressure; High suction pressure.
RESULT: Expansion device stuck in open position.
FIX: Replace expansion device.

PROBLEM: Low head pressure; High suction pressure.
RESULT: Defective compressor valves.
FIX: Replace compressor.

PROBLEM: Low suction pressure; Compressor cool. Ice on indoor coil.
RESULT: Low indoor airflow.
FIX: Increase speed of blower or reduce restriction - replace air filter.

PROBLEM: Low suction pressure; Compressor cool. Ice on indoor coil.
RESULT: Operating below 65F (18C) outdoors.
FIX: Add low ambient kit.

PROBLEM: Low suction pressure; Compressor cool. Ice on indoor coil.
RESULT: Moisture in system.
FIX: Recover refrigerant - evacuate and recharge - replace filter drier.

PROBLEM: High suction pressure; or fluctuating head and suction pressures.
RESULT: Excessive load.
FIX: Recheck load calculation.

PROBLEM: High suction pressure; or fluctuating head and suction pressures.
RESULT: Defective compressor.
FIX: Replace.

PROBLEM: High suction pressure; or fluctuating head and suction pressures.
RESULT: TXV hunting.
FIX: Check TXV bulb clamp - check air distribution on coil - replace TXV.

PROBLEM: High suction pressure; or fluctuating head and suction pressures.
RESULT: Air or non-condensables in system.
FIX: Recover refrigerant, evacuate and recharge.

PROBLEM: Pulsing noise at expansion device or liquid line.
RESULT: Air or non-condensables in system.
FIX: Recover refrigerant, evacuate and recharge.

PROBLEM: Registers sweat.
RESULT: Low indoor airflow.
FIX: Increase speed of blower or reduce restriction - replace air filter.

napoleon air conditioner error codes

napoleon air conditioner codes


See What Our Customers Are Saying:

by GR from Oshawa on Twintech Heating and Cooling

Twintech replaced our aging furnace and air conditioner recently. I highly recommend this company. Their quote was competitive, they were on time and respectful of our home and extremely professional. From the salesman to the installers and the owner who followed up afterward to ensure we were satisfied, we are very pleased with the service. We are looking forward to working with this company for all of our HVAC needs for the years to come. Excellent workmanship and service!

by nathans in Scarborough on Twintech Heating and Cooling

We wanted to get our AC replaced as it was 22-years old and added to this our furnace was costing more and more to repair. So, we decided to get both the furnace and AC replaced.

After going through a few quotes and product reviews we decided to go with Twintech. The three-men crew arrived early in the morning, wasted no time and got to work right away. By 2:00 pm, they were all done. I’ve found their work to be top notch and they were completely professional. I had all my questions answered to my satisfaction both during the progress of their work and at end.

I have pleasure in recommending Twintech to anyone who is looking to get their furnace or Ac replaced

Nathan S.

by Private User on Twintech Heating and Cooling

Our air conditioner died On a Saturday and within hours Dave came out to take a look and discuss replacement/repair options.
The new air conditioner was installed on the Wednesday. The new unit was installed quickly. The installers were friendly and cleaned up afterwards.
We noticed a slight leak around the furnace that night and they came out the next day and fixed the issue. It has been working great and is quieter than our previous unit.
Very satisfied and would highly recommend TwinTech.

by Nancy in Toronto on Twintech Heating and Cooling

I contacted TwinTech to replace my 20-year old A/C. Dave, their service rep, promptly replied and was at my home within 2 hours. He was friendly and knowledgeable and didn't try to upgrade or oversell their A/C units but suggested the best fit for my small 1000 feet bungalow. Although this was during a heatwave and very busy, they were able to fit me in 2 days later. The TwinTech crew installed a 1.5 ton Ducane A/C unit that is now running smoothly while maintaining a constant cooling temperature. The crew were very courteous, professional and efficient and I will definitely recommend TwinTech to family and friends. I much appreciated your great service.
Nancy M., Oshawa

by Private User on Twintech Heating and Cooling

We had a great experience. The guys who installed our a/c did a nice job. Cleaned up.

by Private User on Twintech Heating and Cooling

excellent crew, fast and efficient! Would call them again when I need a new furnace.

by Private User on Twintech Heating and Cooling

Professional, courteous and efficient, don’t need to say more than that! Use them you will not regret it.

by Private User on Twintech Heating and Cooling

TwinTech was a pleasure to deal with from the estimate through installation. We replaced a 28 year old a/c unit with one recommended by TwinTech's sales representative Dave who took the time to go over the product with us and answer any questions. The warranty is for 10 years parts and labour and they will complete the registration for you. Installation was by Greg (owner) and Mitch and Spencer who were quick and efficient and left everything clean and tidy.

by Private User on Twintech Heating and Cooling

Very professional, from the sales consultation and inspection to the final installation. Met every expectations we had for the job. A local business with great client support. We highly recommend. Twintech is a blue chip! Thanks!

by Private User on Twintech Heating and Cooling

I left a live chat message on their website that my air conditioning was not working. Within 1hr a representative called me to discuss my options.
The next day he came to the house to review my needs and give me a price for a new system. Price quoted was less than I expected and the installation was completed the following day. I found their salesman and the installers very knowledgeable and easy to deal with. All my questions were answered. Everything was properly explained in regards to what unit was needed and why, along with instruction where needed for use.
The installers made sure everything was working properly before they left.

Related Links:
ac repair services, furnace repairs pickering, central air conditioner services, whitby air and heating, whitby heating and air, ajax hvac repair, air conditioner repair, hvac repairs, heating repair company, house air conditioner repair, ac repair and service, whitby air conditioning, residential air conditioner repair, residential ac repair, pickering air conditioners, oshawa air conditioners, nearby ac repair, furnace repair ajax, furnace repair pickering, furnace repair oshawa, furnace repairs, furnace repair, hvac repair service, central air conditioner, ajax furnace repair, ajax air conditioners,