If you are an owner of Ruud furnace or operate it at your work, you may encounter with Ruud furnace error codes appearing in the operation process. The tables on the page describe the codes, flashes, blinks and other problem signals and let you understand what is going on with the equipment at a certain moment.


Ruud R801T Furnace Error Code

CODE: 0.
RESULT: Standby.

CODE: C.
RESULT: Compressor on (cooling or heat-pump heat).

CODE: H.
RESULT: Gas heat on.

CODE: F.
RESULT: Continuous fan on.

CODE: 10.
RESULT: 1 hour lockout.

CODE: 11.
RESULT: Failed ignition.

CODE: 12.
RESULT: Low flame sense.

CODE: 13.
RESULT: Flame lost.

CODE: 14.
RESULT: Unexpected flame.

CODE: 20.
RESULT: Twinning fault.

CODE: 22.
RESULT: Main limit open.

CODE: 26.
RESULT: Line and neutral reversed.

CODE: 33.
RESULT: Mrlc (manual reset limit control) (aka roll-out) open.

CODE: 55.
RESULT: Pressure switch stuck closed when should be open.

CODE: 57.
RESULT: Press switch stuck open when should be closed.

CODE: 61.
RESULT: Blower fault-blower unable to run.

CODE: 93.
RESULT: Internal control fault.

Ruud U98V Furnace Error Code

FLAME LED: OFF.
RESULT: No flame is detected.

FLAME LED: Rapid blink.
RESULT: Unexpected flame.

FLAME LED: Slow blink.
RESULT: Marginal flame sense.

FLAME LED: Steady ON.
RESULT: Normal flame detected.

STATUS LED: Steady ON.
RESULT: Furnace.

STATUS LED: 1 Blink.
RESULT: Ignition failure, 1 HR lockout.
FIX: Reboot system.

STATUS LED: 2 Blinks.
RESULT: Pressure switch stuck open, switch will not close when inducer is on.
FIX: Try to manually close the switch, replace the switch, or check blowers and vents for air pressure.

STATUS LED: 3 Blinks.
RESULT: Limit switch open, main limit or roll out control
FIX: Check for a restricted air vent, loose blower wheel, a defective blower, or a dirty air filter.

STATUS LED: 4 Blinks.
RESULT: Pressure switch stuck closed, switch will not open.
FIX: Check for an obstruction in the pressure tubing.

STATUS LED: 5 Blinks.
RESULT: Not applicable.

STATUS LED: 6 Blinks.
RESULT: Line and neutral reversed.
FIX: Control board or the furnace's ground could be defective.

POWER LED: OFF.
RESULT: No power (24 VAC) to control board.

POWER LED: ON.
RESULT: Control is powered.

Ruud R802P Furnace Error Code

FLAME LED: OFF.
RESULT: No flame is detected.

FLAME LED: Rapid Blink.
RESULT: Unexpected Flame.

FLAME LED: Slow Blink.
RESULT: Marginal Flame Sense.

FLAME LED: Steady ON.
RESULT: Normal Flame Detected.

STATUS LED: Steady ON.
RESULT: Normal Fault detected.

STATUS LED: 1 Blink.
RESULT: Ignition failure, 1 HR lockout.

STATUS LED: 2 Blinks.
RESULT: Pressure switch stuck open switch will not close when inducer is on.

STATUS LED: 3 Blinks.
RESULT: Limit switch open main limit or roll-out control.

STATUS LED: 4 Blinks.
RESULT: Pressure switch stuck closed. Switch will not open.

STATUS LED: 5 Blinks.
RESULT: Not applicable.

STATUS LED: 6 Blinks.
RESULT: Line and Neutral reversed.

POWER LED: OFF.
RESULT: No power (24VAC) to control board.

POWER LED: ON.
RESULT: Control is powered.

Ruud R96P Furnace Error Code

GREEN LED: ON.
RESULT: Normal operation.

GREEN LED: 1 Flash.
RESULT: Ignition failure (4 trials).

GREEN LED: 2 Flashes.
RESULT: Pressure switch stuck open.

GREEN LED: 3 Flashes.
RESULT: Limit switches open.

GREEN LED: 4 Flashes.
RESULT: Pressure switch stuck closed.

GREEN LED: 5 Flashes.
RESULT: Twin fault.

GREEN LED: 6 Flashes.
RESULT: Brownout voltage.

GREEN LED: 7 Flashes.
RESULT: Hot and neutral reversed or no ground.

GREEN LED: Continuous.
RESULT: Gas valve relay short.

YELLOW LED: Rapid Blink.
RESULT: Flame out of sequence.

YELLOW LED: Slow Blink.
RESULT: Low flame or no flame.

YELLOW LED: ON.
RESULT: Flame present.


See What Our Customers Are Saying:

by Nancy H. from Oshawa on Twintech Heating and Cooling

Work was performed in a clean and timely manner. The furnace and metal work was performed by the Twintech team (did not require separate contractor to do the metal work). Energy audit was arranged and promised rebates were received. The overall price was very competitive. We have recommended Twintech to several of our friends and family. Awesome job.

by Syd from Whitby on Twintech Heating and Cooling

Grant and Greg installed a heating and AC system in our new Linwood post and beam home. Post and beam can be challenging structures for running ductwork and their high ceilings and open concept frequently frustrate efforts at balancing air flow and controlling temperatures. But these guys did it and did it right the first time. Even the building inspector was impressed with what he saw. More importantly, the boys brought a high degree of trust and integrity to the job. Something in short supply these days.

by jenner iksmom from Oshawa on Twintech Heating and Cooling

Very polite and professional. They removed my o
ld furnace and A/C and installed my new ones. They were efficient and thoroughly cleaned up when they were done! I would highly recommend them!

by Rob from Toronto on Twintech Heating and Cooling

Pro from start to finish. They were able to fix my gas fireplace at very little cost as well.

by murray mcmichael from Ajax on Twintech Heating and Cooling

Excellent installation very knowledgeable gentlemen! Would highly recommend them to all my friends for any hvac work !

by Private User from Private User on Twintech Heating and Cooling

I have used Twintech many times over the years. They always arrive quickly and get the issue fixed. The most recent incident was when my air conditioner broke last week I called Greg at 11:30am and he was at my home by 2:30pm he had the unit fixed by 3:30pm. Twintech are very reliable and honest and they are experts in the field. I have already recommended them to many of my friends. I would not use anyone but them for my heating and air conditioning issues.

by Kate A in Pickering on Twintech Heating and Cooling

I would highly recommend these guys, professional, fast and competitive pricing. I moved into this place with no working AC unit with a 8 month baby, he was able to come with in a week to fix even in the busy summer days. He really values his customers , I am already recommending to my neighbors.

by Private User in Whitby on Twintech Heating and Cooling

Very impressed they arrive to quote even though I had forgotten to call them back to confirm date & time. They showed the day before installation to deliver the unit. Returned the next day as promised at 9am. Project was completed in a professional manner. They even fixed a few things that they noticed were not installed correctly, or to code by previous heating & air contractors we had at our residence before. Would recommend this company to everyone!

by Private User from Bowmanville on Twintech Heating and Cooling

Greg removed old oil furnace and oil tank from basement relocated new Napoleon propane furnace to allow duct work to be rerouted to a much more suitable location. Moved air conditioner to the new furnace. Dave recommended two available grants to assist with cost. They kept to their original quoted price which was substantially lower than a competitors for the same furnace and work. They completed the work as stated when stated and left the area clean and tidy. We are very pleased with the outcome.

by astephenson in Oshawa on Twintech Heating and Cooling

Twintech installed a Goodman furnace and ac init. Very professional install, both units are working well.