If you're looking for help fixing your Heil furnace, look no further! Our comprehensive Heil furnace repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model's error codes..


CODE: Heartbeat.
RESULT: Control has 24 VAC power.

CODE: 2 Flashes.
RESULT: Pressure switch did not open, check for obstructed pressure tubing.

CODE: 3 Flashes.
RESULT: Pressure switch did not close, or re-opened- Check for: excessive wind, proper vent size, defective inducer motor, low inducer voltage, defective pressure switch, inadequate combustion air supply, disconnected or obstructed pressure tubing, low inlet gas pressure, restricted vent, condensate clogged.

CODE: 4 Flashes.
RESULT: Limit circuit fault-a limit or flame rollout is open. Check for: restricted vent, proper vent sizing, loose blower wheel, excessive wind, dirty filter, defective blower motor, defective switch or connections, inadequate combustion air supply.

CODE: 5 Flashes.
RESULT: Abnormal flame proving signal-Flame is proved while gas valve is de-energized. Check for: leaky gas valve, stuck open gas valve.

CODE: 6 Flashes.
RESULT: Failure to ignite or flame sense lost while running. Check for: Flame sensor must not be grounded, low inlet gas pressure, oxide buildup on flame sensor, Manual valve shut off, proper flame sense microamps, gas valve defective or gas valve turned off, defective hot surface igniter, control ground continuity, Inadequate flame carryover or rough ignition, green/yellow wire MUST be connected to furnace sheet metal.

CODE: 7 Flashes.
RESULT: Limit circuit lockout- Lockout occurs if the limit or flame rollout is open longer than 3 minutes. Control will auto reset after 3 hours. Refer to #4.

CODE: 8 Flashes.
RESULT: Gas heating lockout-Control will NOT auto reset. Check for: mis-wired gas valve, defective control valve.

CODE: 10 Flashes.
RESULT: Polarity-Line voltage, polarity reversed. If twinned, refer to twinning kit instructions.

CODE: 1 + 2 Flashes.
RESULT: Blower on after power up- Blower runs for 90 seconds, if unit is powered up during a call for heat (R-W closed) or (R-W) opens during blower on delay.

CODE: 6 + 1 Flashes.
RESULT: Ignition lockout- Control will auto-reset after 3 hours. Refer to #6.

CODE: LED Off.
RESULT: Secondary voltage fuse is open- Check for: door switch not closed, 115VAC at L1 and neutral, 24VAC RED and COM BLUE, 24V Fuse 3A, short circuit in secondary voltage (24VAC wiring).

CODE: LED On.
RESULT: Control circuitry lockout- Auto-reset after one hour.

CODE: LED SOLID.
RESULT: Gas valve relay stuck open- Flame sense circuit failure, software check error, reset power to clear lockout, replace control if status code repeats.


See What Our Customers Are Saying:

by Floreene in Whitby on Twintech Heating and Cooling

My old furnace had finally broken down for the last time when contacted twintech to have a new furnace installed…They were prompt, knowledgeable and very reasonably priced. They did such a great job i tell all my friends and family about this company.

by Damien McIsaac. Ajax on Twintech Heating and Cooling

To whom it may concern, I recently had TwinTech (Greg and Grant Dainty) replace my furnace and service both my gas fireplaces and air conditioning unit. They were professional, courteous and very fair in their pricing. I would gladly recommend TwinTech to anyone needing work done. I can be contacted at 905-626-XXXX.

by Blair N. - Toronto on Twintech Heating and Cooling

My Fiancé and I have relied on Twintech Heating and Cooling now for the better part of the last 10 years. In that time, Greg has installed a furnace, an air conditioner, and a heat-pump at our residence in Toronto. In each instance Greg and his team were a pleasure to deal with. They were courteous and professional throughout the whole process and the quality of their work is first rate. Our experiences have always been extremely positive and we have referred his services numerous times to our friends and family. Without hesitation, I would recommend Greg and TwinTech Heating and Cooling to anyone looking to service or replace their existing heat/AC equipment

See What Our Customers Are Saying:

by Robert Rogers on Twintech Heating and Cooling

Very pleased with the professional service that TwinTech Heating and Cooling provided in replacing my furnace. I got several quotes from different service providers. Their price was excellent and they explained the features very well. We are very glad we went with TwinTech and highly recommend their services.

by Robert Mizuno on Twintech Heating and Cooling

We were new homeowners in need of a second opinion. TwinTech Heating & Cooling were Amazing and professional. Very knowledgeable and great service all around. Recommend to anyone looking for honest and reliable services. Treated with respect and care. Thank you Greg, Mitch and Bob!

by Ruth on Twintech Heating and Cooling

TwinTech is an excellent and honest company! I called them for a second opinion after being told by another company that I needed to replace my furnace. Turns out this was not the case at all! I did not need a new furnace. TwinTech did not push to make an unnecessary sale and saved me from a huge expense. Bob and Mitch were extremely professional and above all honest! I definitely recommend TwinTech!

by Anna Chin on Twintech Heating and Cooling

Amazing experience with TwinTech Heating & Cooling! Their team was professional, knowledgeable, and efficient from start to finish. They installed my new furnace quickly and left everything spotless. The technicians took the time to explain everything and made sure I was comfortable with the system before they left. Great customer service and fair pricing. I highly recommend them for anyone needing HVAC services!

by Connor Agnew on Twintech Heating and Cooling

Great experience all around. Bob was sharp and easy to talk to, and Greg handled the installation perfectly. Would hire them again in a heartbeat.

How Does a Ductless Heat Pump Work?

  • SUBMITTED BY:
  • TWINTECH HEATING & COOLING
  • - November 28, 2023

A ductless heat pump, also known as a mini-split system, is a type of heating, ventilation, and air conditioning (HVAC) system that provides both heating and cooling to a building without the need for traditional ductwork. Here's a basic overview

Read More

What Causes My AC to Leak?

  • SUBMITTED BY:
  • TWINTECH HEATING & COOLING
  • - March 12, 2024

An air conditioner (AC) leaking water can be caused by various issues. Here are some common reasons: Clogged or Dirty Air Filter: A dirty or clogged air filter can restrict airflow, causing the evaporator coil to freeze and eventually thaw,

Read More

Whitby Furnace Repair

  • SUBMITTED BY:
  • TWINTECH HEATING & COOLING
  • - January 9, 2025

When it comes to reliable furnace repair services in Whitby, Ontario, TWINTECH Heating & Cooling stands out as a trusted provider. Owned and operated by Grant and Greg Dainty, third-generation HVAC technicians, TWINTECH offers comprehensive HVAC

Read More

Everything You Need to Know About Your Amana Heat Pump

  • SUBMITTED BY:
  • TWINTECH HEATING & COOLING
  • - November 15, 2023

Amana is a brand that manufactures a variety of heating, ventilation, and air conditioning (HVAC) products, including heat pumps. Heat pumps are devices that can provide both heating and cooling by transferring heat between the indoor an

Read More