If you're looking for help fixing your luxaire air conditioner, look no further! Our comprehensive luxaire air conditioner repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model's error codes.


CODE: E0.
RESULT: Indoor EEPROM (Electrically Erasable Programmable Read-Only Memory) error.

CODE: E1.
RESULT: Indoor and outdoor unit communication malfunction.

CODE: E3.
RESULT: Indoor fan speed malfunction.

CODE: E4.
RESULT: Indoor room temperature sensor error.

CODE: E5.
RESULT: Evaporator coil temperature sensor error.

CODE: EC.
RESULT: Refrigerant leak detection system malfunction.

CODE: EE.
RESULT: Water level alarm malfunction.

CODE: E8.
RESULT: Dual indoor unit (twin model only) communication malfunction.

CODE: E9.
RESULT: Other twin model malfunction.

CODE: F0.
RESULT: Overload protection.

CODE: F1.
RESULT: Outdoor temperature sensor error.

CODE: F2.
RESULT: Outdoor condenser pipe sensor error.

CODE: F3.
RESULT: Discharge air temperature sensor error.

CODE: F4.
RESULT: Outdoor EEPROM (Electrically Erasable Programmable Read-Only Memory) error.

CODE: F5.
RESULT: Outdoor fan speed (DC fan motor only) malfunction.

CODE: F6.
RESULT: T2b sensor error.

CODE: F7.
RESULT: Auto-lifting panel communication error.

CODE: F8.
RESULT: Auto-lifting panel malfunction.

CODE: F9.
RESULT: Auto-lifting panel is open.

CODE: P0.
RESULT: Inverter module IPM protection.

CODE: P1.
RESULT: High/Low voltage protection.

CODE: P2.
RESULT: Compressor top overheating protection.

CODE: P3.
RESULT: Outdoor low temperature protection.

CODE: P4.
RESULT: Compressor drive error.

CODE: P5.
RESULT: Mode conflict.

CODE: P6.
RESULT: Compressor low-pressure protection.

CODE: P7.
RESULT: Outdoor IGBT sensor error.

Luxaire Central Controller Fault Codes.

CODE: H3.
RESULT: Outdoor adding malfunction (valid for host unit).

CODE: H2.
RESULT: Outdoor decreasing malfunction (valid for host unit).

CODE: H1.
RESULT: Net communication malfunction.

CODE: EF.
RESULT: Other malfunction.

CODE: E4-T4.
RESULT: Temp. Sensor malfunction.

CODE: E3-T3.
RESULT: Temp. Sensor malfunction.

CODE: E2.
RESULT: Sensor malfunction.

CODE: E1-E0.
RESULT: Communication malfunction Phase sequence or lack of phase.

CODE: PF.
RESULT: Other Protection.

CODE: PE.
RESULT: Oil Balance.

CODE: PD.
RESULT: Oil Return.

CODE: PA.
RESULT: Defrost Protection.

CODE: P8.
RESULT: Compressor Current 3rd Protection.

CODE: P7.
RESULT: Compressor Current 2nd Protection.

CODE: P5.
RESULT: Condenser High Temp. Protection.

CODE: P4.
RESULT: Discharge Pipe Temp. Protection.

CODE: P3.
RESULT: Compressor Current 1st Protection.

CODE: P2.
RESULT: Discharge Low- pressure Protection.

CODE: P1-P0.
RESULT: Discharge High- pressure Protection Compressor High Temp. Protection.

Malfunction Code of Outdoor unit.

CODE: E1.
RESULT: Phase sequence error.

CODE: E2.
RESULT: Communication malfunction between indoor/outdoor units.

CODE: E3.
RESULT: T3 temperature sensor malfunction.

CODE: E4.
RESULT: T4 temperature sensor malfunction.

CODE: E5.
RESULT: T5 temperature sensor malfunction.

CODE: E6.
RESULT: Water-level alarm malfunction.

Luxaire Central Air Conditioning Error Codes,

CODE: EF.
RESULT: Other malfunction PF Other Protection.

CODE: EE.
RESULT: Water level checking malfunction PE Reserve.

CODE: ED.
RESULT: Outdoor protection PD Reserve.

CODE: EC.
RESULT: Clear malfunction PC Reserve.

CODE: EB.
RESULT: Inverter Module Protection PB Reserve.

CODE: EA.
RESULT: Compressor Over-current (4 times) PA Reserve.

CODE: E9.
RESULT: Communication malfunction between PCB and Display board P9 Reserve.

CODE: E8.
RESULT: Fan motor checking out of control P8 Compressor Over-current.

CODE: E7.
RESULT: EEPROM malfunction P7 Power Lack/Over Volt Protection.

CODE: E6.
RESULT: Over-zero checking malfunction P6 Discharge Low-pressure Protection.

CODE: E5.
RESULT: T3 sensor malfunction P5 Discharge High-pressure Protection.

CODE: E4.
RESULT: T2B sensor malfunction P4 Discharge Pipe Temp. Protection.

CODE: E3.
RESULT: T2A sensor malfunction P3 Compressor Temp. Protection.

CODE: E2.
RESULT: T1 sensor malfunction P2 Condenser High Temp. Protection.

CODE: E1.
RESULT: Communication malfunction P1 Anti-cooling or Defrost Protection.

CODE: E0.
RESULT: Phase sequence or lack of phase P0 Evaporator Temp. Protection.

CODE: 03#.
RESULT: CCM/PC(gateway) Communication Malfunction.

CODE: 02#.
RESULT: CCM/Function Module Communication Malfunction.

CODE: 01#.
RESULT: CCM/NIM Communication Malfunction.

CODE: 00#.
RESULT: CCM/PCB Communication Malfunction.

Luxaire Wall Mounted Type Ac Error Codes.

CODE: E7.
RESULT: Communication fault between indoor and outdoor units.

CODE: E1.
RESULT: Room temperature sensor failure.

CODE: E4.
RESULT: Indoor EEPROM error.

CODE: E14.
RESULT: Indoor fan motor malfunction.

CODE: F12.
RESULT: Outdoor EEPROM error.

CODE: F1.
RESULT: The protection of IPM.

CODE: F22.
RESULT: Overcurrent protection of AC electricity for the outdoor model.

CODE: F3.
RESULT: Communication fault between the IPM and outdoor PCB.

CODE: F19.
RESULT: Power voltage is too high or low.

CODE: F4.
RESULT: Overheat protection for Discharge temperature.

CODE: F8.
RESULT: Outdoor DC fan motor fault.

CODE: F21.
RESULT: Defrost temperature sensor failure.

CODE: F7.
RESULT: Suction temperature sensor failure.

CODE: F6.
RESULT: Ambient temperature sensor failure.

CODE: F25.
RESULT: Discharge temperature sensor failure.

CODE: F11.
RESULT: deviate from the normal for the compressor.

CODE: F28.
RESULT: Loop of the station detect error.

CODE: F2.
RESULT: Overcurrent of the compressor.

CODE: F23.
RESULT: Overcurrent protection for single-phase of the compressor.


See What Our Customers Are Saying:

by Bill, Whitby on Twintech Heating and Cooling

Reasonable price and the workmanship was prompt and timely and the employees were great to deal with.

by Nadia, Toronto on Twintech Heating and Cooling

The sales process was friendly, informative, and very consultative. They worked hard to earn our business by taking a careful look around our home to assess our needs, providing a lot of information about the product, and answering all our questions and finding the right solution for our home at a competitive price. They prepared us very well for what to expect on installation day, and the installation went very smoothly - no surprises, all very professional! They gave us a call after installation to ensure we were happy with the work. We're very happy that we chose to work with TwinTech to get our new furnace.

by Private User on Twintech Heating and Cooling

Twintech promptly responded to request for quotation. They were thorough and helpful in explaining options. The quote was very competitive. Installation of new furnace was very professionally completed. Excellent work.

by Rita, Scarborough on Twintech Heating and Cooling

When our old oil furnace finally broke down we decided it was time to finally convert to natural gas and finally install central air conditioning at the same time. Knowing it was going to be a significant investment for us, we wanted to make the right choice. Twintech came highly recommended by a friend and we were not disappointed. From the first contact with the salesperson, until the final touches on the installation, we were so pleased with their service. Everyone from the company was so friendly, efficient and a pleasure to deal with. Best of all, the cost was very competitive. We would certainly recommend Twintech to anyone requiring HVAC work in their home.

by Bob S, Pickering on Twintech Heating and Cooling

Mitch from Twintech came out for our annual furnace inspection. We found him to be friendly, conscientious & he left the work area clean. We were also very impressed with the thoroughness of the job he did. This is the 2nd job we’ve had Twintech do for us & have been very happy with the results for each. We highly recommend this company. Thank you, Mitch, Dave & Greg.

by Brent L on Twintech Heating and Cooling

Work was done on schedule, professionally, according to quote and with minimal inconvenience to building users. Very happy with the end result. The only area for improvement from my experience - need more timely quoting process.

by Karen on Twintech Heating and Cooling

The team was great! Very knowledgeable, professional and extremely helpful. A few days after install the unit didn’t seem to be working, user error, but within minutes of contacting them..on a Saturday.. a tech was on the phone troubleshooting with us. I highly recommend Twintech for your cooling or heating needs. They stand by their products and a pleasure to deal with.

by Rob on Twintech Heating and Cooling

During the hottest week in the summer our old A/C decided to call it quits. I called Twintech Heating & Cooling after receiving a referral from a family member; came highly rated for being an honest, family-run business, who appreciates their customers. Dave was able to accommodate my hectic schedule and book a late evening appointment to walk through the specifics. Greg and Mitch arrived exactly on time a few days later, were very polite and friendly, and within a couple of hours had a new unit up and running. I also received a follow-up call to ensure we were happy with the Amana.

by Linda Robinson on Twintech Heating and Cooling

They were on time and very professional. I'm so glad I decided to go with Twintech, thanks!

by Famcam1953 on Twintech Heating and Cooling

Timely and appreciated - this was during the hottest days this year when our Air and Furnace way.
Efficient. Professional. No BS or overselling. What was promised, was delivered at a cost-effective price point.
Down to earth.

See What Our Customers Are Saying:

by Aaron on Twintech Heating and Cooling

We are very happy to recommend this company to everyone. Our furnace broke down on Sunday morning. We phoned them and before noon Grant the owner showed up. He worked on the furnace for about a hour not wanting to give up to fix the problem. The furnace was 17 years old. I was the one talking about replacing it. End result was the next day it was all done. On the Sunday Bob came over with heaters to warm up the house. We decided to replace the water heater at the same time. Thanks Grant for the excellent work. Thumbs up.

by Linda on Twintech Heating and Cooling

Right on time. Explained how to work the HRV in a different way so the house would not be so dry. Changed my whole house water filter for me as well. Friendly, helpful, caring service!

by Robert Rogers on Twintech Heating and Cooling

Very pleased with the professional service that TwinTech Heating and Cooling provided in replacing my furnace. I got several quotes from different service providers. Their price was excellent and they explained the features very well. We are very glad we went with TwinTech and highly recommend their services.

by Robert Mizuno on Twintech Heating and Cooling

We were new homeowners in need of a second opinion. TwinTech Heating & Cooling were Amazing and professional. Very knowledgeable and great service all around. Recommend to anyone looking for honest and reliable services. Treated with respect and care. Thank you Greg, Mitch and Bob!

by Ruth on Twintech Heating and Cooling

TwinTech is an excellent and honest company! I called them for a second opinion after being told by another company that I needed to replace my furnace. Turns out this was not the case at all! I did not need a new furnace. TwinTech did not push to make an unnecessary sale and saved me from a huge expense. Bob and Mitch were extremely professional and above all honest! I definitely recommend TwinTech!

How Do Heat Pumps Perform in Cold Weather?

  • SUBMITTED BY:
  • TWINTECH HEATING & COOLING
  • - January 28, 2024

Heat pumps can operate in cold weather, but their performance may be affected depending on various factors such as outdoor temperature, system design, and technology used. Here's how heat pumps generally perform in cold weather: Efficien

Read More

Preventing Your AC Unit From Breaking Down

  • SUBMITTED BY:
  • TWINTECH HEATING & COOLING
  • - July 30, 2024

Preventing your AC unit from breaking down involves regular maintenance and a few proactive measures. Here are some key tips to help keep your AC running smoothly: Regular Maintenance Scheduled Inspections: Professional Tune-Ups: Have a prof

Read More

How to Safely Turn Off Your Heat Pump

  • SUBMITTED BY:
  • TWINTECH HEATING & COOLING
  • - November 19, 2023

Turning off your heat pump safely involves a few simple steps. Keep in mind that heat pumps operate differently from traditional heating systems, so it's important to follow specific guidelines. Here's a general guide on how to safely turn of

Read More

Twintech: Reliable Furnace Repair in Pickering

  • SUBMITTED BY:
  • TWINTECH HEATING & COOLING
  • - September 9, 2024

Reliable Furnace Repair in Pickering | Twintech Heating and Cooling When the cold weather hits Pickering, a reliable furnace is essential to keep your home warm and comfortable. At Twintech Heating and Cooling, we specialize in furnace repair serv

Read More