$49 / month O.A.C Including Install
$49 / month O.A.C Including Install

24 / 7 Emergency Service Available. Call Us Now: 1.844.894.6832

Durham Region Air Conditioning Repair, Service and Installation

CLICK HERE FOR A FREE QUOTATION

The Payne gas furnace has built in diagnostics and is designed to assist with the identification and correction of faults. The furnace utilizes an LED, to describe its condition.This can be viewed through a port on the blower access panel. You can take corrective action in response to any faults indicated by the LED.


The number of short flashes of the LED represents the first digit of the two digit fault code. The number of long flashes of the LED represents the second digit of the fault code.


CODE: RED LED1 ON.
RESULT: Furnace is operating in emergency heat.

CODE: RED LED2 ON.
RESULT: The microprocessor has malfunctioned. To reset: Put setup switch "SW-1" in the "ON" position nad jumper thermostat terminals "R", "W/W1" and "Y/Y2" simultaneously with the door switch pushed in and power to the unit "ON". Disconnect jumper and place setup switch in the "OFF" position. If LED2 reappears, replace main control board.

CODE: YELLOW LED3 ON.
RESULT: Furnace is operating in high heat.

CODE: GREEN LED4 ON.
RESULT: Furnace is operating in low heat.

CODE: RED LED2 FLASHING.
RESULT: Line voltage polarity is reversed.

CODE: 11.
RESULT: NO FAULT IN RECENT HISTORY DISPLAY- Indicates no faults have occurred within the last five cycles. To read recent fault history, put setup switch "SW-1" in the "ON" position. To clear recent fault history, put setup switch "SW-1" in the "ON" position and jumper thermostat terminals "R", "W/W1" and "Y/Y2" simultaneously until an "11" is flashed.

CODE: 12.
RESULT: BLOWER CALIBRATION LOCKOUT- Indicates RPM calculated for low heat was less than 250 RPM or greater than 1300 RPM on two successive attempts. Auto reset after three hours. Reset power and refer to fault #44 section.

CODE: 13.
RESULT: LIMIT SWITCH LOCKOUT- Indicates the occurrence of 10 successive limit trips during high heat or three successive limit trips during low heat. Auto reset after three hours. Check for *Improper or misaligned limit and/or limit shield. *Improper high or low heat gas input adjustment. *Stuck high heat solenoid in gas valve.

CODE: 14.
RESULT: IGNITION LOCKOUT- Control will auto-reset after three hours. Refer to #34.

CODE: 21.
RESULT: INVALID MODEL SELECTION- Indicates model plug is missing or incorrect. See wiring diagram for correct connector jumper location.

CODE: 22.
RESULT: SETUP ERROR- Indicates setup switch "SW-1" or "SW-6" is positioned improperly. The following combinations will cause the fault: *Thermostat call with "SW-1" "ON", or Thermostat call with "SW-6" "ON", or "SW-1" and "SW-6" both "ON" together.

CODE: 23.
RESULT: INVALID BLOWER AIRFLOW SELECTION- Indicates improper "A/C" or "CF" switch setting. The 042 and 14 units can deliver 1-1/2 to 3-1/2 tons A/C and 600 to 1400 CFM for continuous fan. The 060 and 20 unit can deliver 2 to 5 tons A/C and 800 to 2000 CFM for continuous fan. If code is flashing, unit will default tp closest allowable airflow.

CODE: 24.
RESULT: SECONDARY VOLTAGE FUSE IS OPEN Check for: - Short circuit in secondary voltage (24VAC) wiring. PRESSURE SWITCH DID NOT CLOSE OR REOPENED - If open longer than five minutes, inducer shuts off for 15 minutes before retry. Check for: - Excessive wind.

CODE: 31.
RESULT: Proper vent sizing -- Defective inducer motor - Low inducer voltage (115VAC) - Defective pressure switch - Inadequate combustion air supply - Restricted vent - Disconnected or obstructed pressure tubing - Low inlet gas pressure (if LGPS used) If it opens during blower ondelay period, blower will come on for the selected blower off-delay.

CODE: 33.
RESULT: LIMIT CIRCUIT FAULT - Indicates a limit, or flame rollout is open. Blower will run for 4 minutes or until open switch remakes whichever is longer. If open longer than 3 minutes, code changes to lockout #13. If open less than 3 minutes status code #33 continues to flash until blower shuts of Flame rollout switch requires manual reset. Check for: - Restricted vent - Proper vent sizing - Loose blower wheel - Excessive wind - Dirty filter or restricted duct system. - Defective blower motor or capacitor. - Defective switch or connections. - Inadequate combustion air supply (Flame Roll-out Switch open).

CODE: 34.
RESULT: IGNITION PROVING FAILURE - Control will try three more times before lockout #14 occurs. If flame signal lost during blower on-delay period, blower will come on for the selected blower off-delay. Check for: - Control ground continuity - Flame sensor must not be grounded - Oxide buildup on flame sensor (clean with fine steel wool) - Proper flame sense microamps (.5 microamps D.C. min., 4.0 - 6.0 nominal). - Gas valve defective or gas valve turned off - Manual valve shut-off - Defective Hot Surface Ignitor - Low inlet gas pressure - Inadequate flame carryover or rough ignition - Green/Yellow wire MUST be connected to furnace sheet metal.

CODE: 41.
RESULT: BLOWER OUTSIDE VALID SPEED RANGE- Indicates the blower is not operating at the calculated RPM. If this fault occurs in conjunction with fault #44 check wiring to motor otherwise refer to the trouble-shooting guide.

CODE: 42.
RESULT: INDUCER OUTSIDE VALID SPEED RANGE- Indicates the inducer is not operating at the calculated RPM. Or it has not started within 10 seconds after a call for heat. Check wiring to motor otherwise refer to the troubleshooting guide.

CODE: 43.
RESULT: PRESSURE SWITCH CALIBRATION FAULT- Indicates the low and high pressure switch "make" points during high heat purge are not within calibration range. Check for: -Plugged condensate drain Water in vent piping, possibly sagging pipe -Improper pressure switch wiring or pressure switch tubing connections -Failed or "out of calibration" pressure switches.

CODE: 44.
RESULT: BLOWER CALIBRATION FAULT- Indicates the calculated blower speed is below 250 or above 1300 RPM. Unit will default to low or high heat mode if possible. If this fault occurs in conjunection with fault #41, check wiring to motor otherwise refer to the trouble shooting guide. If this fault occurs by itself, check for undersized ductwork, or excessive static caused by a dirty filter, or closed registers.

CODE: 45.
RESULT: CONTROL CIRCUITRY LOCKOUT -Auto-reset after one hour lockout due to; - Gas valve relay stuck open - Flame sense circuit failure - Software check error Reset power to clear lockout. Replace control if status code repeats.


See What Our Customers Are Saying:

by Craig in Whitby on Twintech Heating and Cooling

I called Twintech during the Covid 19 crisis because our furnace was broken and it was still very cold during the nights. Dave answered all of my questions by phone but wanted to come have a look but only if our family felt comfortable having someone visit during the uncertainty surrounding the pandemic and was able to attend that very same affternoon.

He was very courteous and informative but most importantly he respected his and our safety by wearing medical gloves in our home and maintaining proper physical distancing. He reviewed the various options of the products that suited our needs going over not only price but quality of workmanship, warrantees and where the product was manufactured which were all important factors in making such a large purchase. You could tell that Dave had been in this industry for a very long time.

The installation was done by a fine young gentleman the very next day and we now have a toasty warm home to ride out this crisis in while humming along at 96% efficiency!

I would recommend this very professional, small family business for anyone in need of HVAC equipment or maintenance.

by Lucy in Markham on Twintech Heating and Cooling

My special thanks to Twintech teams! They had replaced my furnace and A/C, and installed a new humidifier for me 2 weeks ago. Dave, the sales manager, not only provided me with an honest quote on the best HVAC products with best quality and warranties, he also arranged portable heaters for me and sent supporting docs to energy company for energy audit. Above and beyond service!

Greg, Grant, Mitch had worked tirelessly and professionally to perform the HVAC installation. They worked with professional tools, and performed proper measurement readings after installation. They are very patient with all my questions, and very pleasant to communicate.

Great work guys! This company sure knows their products and they stand behind their services. My home comfort level has improved! I am glad that I can support an ethical and honest local family business.

by ddame on Twintech Heating and Cooling

Professional, flexible on price and delivered on time...well done. All you can ask for when getting a new furnace.

by nicole.el.thorn on Twintech Heating and Cooling

The work was done quickly and professionally. Workers were really polite and easy to work with.
Product works great!

by Gary in London on Twintech Heating and Cooling

Furnace broke down on a Wednesday, shopped around for prices and Friday Twintechs name came up from a referral from my wife's work. Called Dave 11 am, he came over around 1 pm. Gave me a very good price, I accepted. The guys were there two hours later to take the old furnace out and install the new one. All finished by 6:30pm. Finally heat.
They were very pleasant and helpful. As a result we are doing our A/C later this year with this company.

by Shawn L in Whitby on Twintech Heating and Cooling

After some extensive research, we settled on Twintech for our new furnace. The service - from Dave's initial visit - through to the installation was absolutely fantastic.

Dave was super-patient with our many questions, did not try to "up-sell" us into buying things we don't need, knowledgeable, friendly and all-around an excellent Advisor.

I've forgotten the names of the installers but they were superb as well. They showed up on-time, did all the work with no mess or intrusion, removed the old furnace and installed the new one in one day; all with no impacts to our day-to-day life.

I cannot recommend Twintech enough, especially over any of 'bigger guys' who tried to sell us a bunch of thing we don't need. Twintech were fantastic and my wife and I are very pleased with our purchase.

by Stephen from Pickering on Twintech Heating and Cooling

From the minute I met Dave and discussed my new furnace needs I knew I was in good hands. He was patient, knowledgeable and very professional through the quotation process.

Grant and Greg did an outstanding job on the install. They did a great job of explaining the defects with my old furnace. The quality of the installation was excellent and the attention to detail was on another level. The old adage “You get what you pay for” couldn’t be more true as I feel I received great value, skilled expertise and high quality customer service. I highly recommend Twintech for all your heating and cooling needs.

by Arthur on Twintech Heating and Cooling

Glad to have found a not-too-big local firm that provided the needed expertise, quality workmanship, and competitive pricing as well. In and out in one day, removed the old units, did a nice job installing all of the new units, and left no debris. Even have a service contract that far outshined the big company offerings. Would definitely recommend them.

by Leriksen on Twintech Heating and Cooling

Appreciated a quick response to my request. Dave and Greg were very professional and made the experience seamless.

by petesalmon938 from Pickering on Twintech Heating and Cooling

Very professional through the entire process. Installation and removel was done on a sloppy winter day, they put down runners on the floors and stairs and when they left, there wasn;t any sign of someone being in our house. Furnace works great as promised.

See What Our Customers Are Saying:

by Robert Rogers on Twintech Heating and Cooling

Very pleased with the professional service that TwinTech Heating and Cooling provided in replacing my furnace. I got several quotes from different service providers. Their price was excellent and they explained the features very well. We are very glad we went with TwinTech and highly recommend their services.

by Robert Mizuno on Twintech Heating and Cooling

We were new homeowners in need of a second opinion. TwinTech Heating & Cooling were Amazing and professional. Very knowledgeable and great service all around. Recommend to anyone looking for honest and reliable services. Treated with respect and care. Thank you Greg, Mitch and Bob!

by Ruth on Twintech Heating and Cooling

TwinTech is an excellent and honest company! I called them for a second opinion after being told by another company that I needed to replace my furnace. Turns out this was not the case at all! I did not need a new furnace. TwinTech did not push to make an unnecessary sale and saved me from a huge expense. Bob and Mitch were extremely professional and above all honest! I definitely recommend TwinTech!

by Anna Chin on Twintech Heating and Cooling

Amazing experience with TwinTech Heating & Cooling! Their team was professional, knowledgeable, and efficient from start to finish. They installed my new furnace quickly and left everything spotless. The technicians took the time to explain everything and made sure I was comfortable with the system before they left. Great customer service and fair pricing. I highly recommend them for anyone needing HVAC services!

by Connor Agnew on Twintech Heating and Cooling

Great experience all around. Bob was sharp and easy to talk to, and Greg handled the installation perfectly. Would hire them again in a heartbeat.

The Essential Guide to Air Conditioner Home Ownership

  • SUBMITTED BY:
  • TWINTECH HEATING & COOLING
  • - August 31, 2024

Owning an air conditioner is not just about enjoying cool, comfortable air during the sweltering summer months—it's about ensuring your unit runs efficiently, lasts longer, and provides value for your investment. Whether you're a new ho

Read More

How Does an AC Unit Normally Function?

  • SUBMITTED BY:
  • TWINTECH HEATING & COOLING
  • - May 5, 2024

An air conditioning (AC) unit works by extracting heat from inside a building and transferring it outside, thereby cooling the indoor air. Here's a basic rundown of how a typical AC unit functions: Evaporation: The process begins with a

Read More

Are Portable ACs at all useful if you have no other options?

  • SUBMITTED BY:
  • TWINTECH HEATING & COOLING
  • - April 21, 2023

I have a friend who lives in an apartment that does not allow window units to be placed. Seems their only option is one of the portable ACs that stand on the floor that you just use the vent / exhaust hose going out the window. This would only

Read More

Most Common AC Error Codes

  • SUBMITTED BY:
  • TWINTECH HEATING & COOLING
  • - July 4, 2024

Air conditioners (AC) come with built-in error codes that help diagnose issues. Here's a list of some of the most common AC error codes and their meanings: General AC Error Codes E1: Indoor unit temperature sensor error E2: Indoor unit

Read More