If you're looking for help fixing your luxaire air conditioner, look no further! Our comprehensive luxaire air conditioner repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model's error codes.


CODE: E0.
RESULT: Indoor EEPROM (Electrically Erasable Programmable Read-Only Memory) error.

CODE: E1.
RESULT: Indoor and outdoor unit communication malfunction.

CODE: E3.
RESULT: Indoor fan speed malfunction.

CODE: E4.
RESULT: Indoor room temperature sensor error.

CODE: E5.
RESULT: Evaporator coil temperature sensor error.

CODE: EC.
RESULT: Refrigerant leak detection system malfunction.

CODE: EE.
RESULT: Water level alarm malfunction.

CODE: E8.
RESULT: Dual indoor unit (twin model only) communication malfunction.

CODE: E9.
RESULT: Other twin model malfunction.

CODE: F0.
RESULT: Overload protection.

CODE: F1.
RESULT: Outdoor temperature sensor error.

CODE: F2.
RESULT: Outdoor condenser pipe sensor error.

CODE: F3.
RESULT: Discharge air temperature sensor error.

CODE: F4.
RESULT: Outdoor EEPROM (Electrically Erasable Programmable Read-Only Memory) error.

CODE: F5.
RESULT: Outdoor fan speed (DC fan motor only) malfunction.

CODE: F6.
RESULT: T2b sensor error.

CODE: F7.
RESULT: Auto-lifting panel communication error.

CODE: F8.
RESULT: Auto-lifting panel malfunction.

CODE: F9.
RESULT: Auto-lifting panel is open.

CODE: P0.
RESULT: Inverter module IPM protection.

CODE: P1.
RESULT: High/Low voltage protection.

CODE: P2.
RESULT: Compressor top overheating protection.

CODE: P3.
RESULT: Outdoor low temperature protection.

CODE: P4.
RESULT: Compressor drive error.

CODE: P5.
RESULT: Mode conflict.

CODE: P6.
RESULT: Compressor low-pressure protection.

CODE: P7.
RESULT: Outdoor IGBT sensor error.

Luxaire Central Controller Fault Codes.

CODE: H3.
RESULT: Outdoor adding malfunction (valid for host unit).

CODE: H2.
RESULT: Outdoor decreasing malfunction (valid for host unit).

CODE: H1.
RESULT: Net communication malfunction.

CODE: EF.
RESULT: Other malfunction.

CODE: E4-T4.
RESULT: Temp. Sensor malfunction.

CODE: E3-T3.
RESULT: Temp. Sensor malfunction.

CODE: E2.
RESULT: Sensor malfunction.

CODE: E1-E0.
RESULT: Communication malfunction Phase sequence or lack of phase.

CODE: PF.
RESULT: Other Protection.

CODE: PE.
RESULT: Oil Balance.

CODE: PD.
RESULT: Oil Return.

CODE: PA.
RESULT: Defrost Protection.

CODE: P8.
RESULT: Compressor Current 3rd Protection.

CODE: P7.
RESULT: Compressor Current 2nd Protection.

CODE: P5.
RESULT: Condenser High Temp. Protection.

CODE: P4.
RESULT: Discharge Pipe Temp. Protection.

CODE: P3.
RESULT: Compressor Current 1st Protection.

CODE: P2.
RESULT: Discharge Low- pressure Protection.

CODE: P1-P0.
RESULT: Discharge High- pressure Protection Compressor High Temp. Protection.

Malfunction Code of Outdoor unit.

CODE: E1.
RESULT: Phase sequence error.

CODE: E2.
RESULT: Communication malfunction between indoor/outdoor units.

CODE: E3.
RESULT: T3 temperature sensor malfunction.

CODE: E4.
RESULT: T4 temperature sensor malfunction.

CODE: E5.
RESULT: T5 temperature sensor malfunction.

CODE: E6.
RESULT: Water-level alarm malfunction.

Luxaire Central Air Conditioning Error Codes,

CODE: EF.
RESULT: Other malfunction PF Other Protection.

CODE: EE.
RESULT: Water level checking malfunction PE Reserve.

CODE: ED.
RESULT: Outdoor protection PD Reserve.

CODE: EC.
RESULT: Clear malfunction PC Reserve.

CODE: EB.
RESULT: Inverter Module Protection PB Reserve.

CODE: EA.
RESULT: Compressor Over-current (4 times) PA Reserve.

CODE: E9.
RESULT: Communication malfunction between PCB and Display board P9 Reserve.

CODE: E8.
RESULT: Fan motor checking out of control P8 Compressor Over-current.

CODE: E7.
RESULT: EEPROM malfunction P7 Power Lack/Over Volt Protection.

CODE: E6.
RESULT: Over-zero checking malfunction P6 Discharge Low-pressure Protection.

CODE: E5.
RESULT: T3 sensor malfunction P5 Discharge High-pressure Protection.

CODE: E4.
RESULT: T2B sensor malfunction P4 Discharge Pipe Temp. Protection.

CODE: E3.
RESULT: T2A sensor malfunction P3 Compressor Temp. Protection.

CODE: E2.
RESULT: T1 sensor malfunction P2 Condenser High Temp. Protection.

CODE: E1.
RESULT: Communication malfunction P1 Anti-cooling or Defrost Protection.

CODE: E0.
RESULT: Phase sequence or lack of phase P0 Evaporator Temp. Protection.

CODE: 03#.
RESULT: CCM/PC(gateway) Communication Malfunction.

CODE: 02#.
RESULT: CCM/Function Module Communication Malfunction.

CODE: 01#.
RESULT: CCM/NIM Communication Malfunction.

CODE: 00#.
RESULT: CCM/PCB Communication Malfunction.

Luxaire Wall Mounted Type Ac Error Codes.

CODE: E7.
RESULT: Communication fault between indoor and outdoor units.

CODE: E1.
RESULT: Room temperature sensor failure.

CODE: E4.
RESULT: Indoor EEPROM error.

CODE: E14.
RESULT: Indoor fan motor malfunction.

CODE: F12.
RESULT: Outdoor EEPROM error.

CODE: F1.
RESULT: The protection of IPM.

CODE: F22.
RESULT: Overcurrent protection of AC electricity for the outdoor model.

CODE: F3.
RESULT: Communication fault between the IPM and outdoor PCB.

CODE: F19.
RESULT: Power voltage is too high or low.

CODE: F4.
RESULT: Overheat protection for Discharge temperature.

CODE: F8.
RESULT: Outdoor DC fan motor fault.

CODE: F21.
RESULT: Defrost temperature sensor failure.

CODE: F7.
RESULT: Suction temperature sensor failure.

CODE: F6.
RESULT: Ambient temperature sensor failure.

CODE: F25.
RESULT: Discharge temperature sensor failure.

CODE: F11.
RESULT: deviate from the normal for the compressor.

CODE: F28.
RESULT: Loop of the station detect error.

CODE: F2.
RESULT: Overcurrent of the compressor.

CODE: F23.
RESULT: Overcurrent protection for single-phase of the compressor.


See What Our Customers Are Saying:

by Private User on Twintech Heating and Cooling

It was a refreshing experience interacting with the Twintech team. From Bob, the sales consultant, who articulated in layman's terms all the options available and reasons for making any selection. This was done without the prevailing pressure tactics so commonplace today.

Before proceeding Mitch, the technician, at our request conducted a service check on our 30 yr old furnace. His report was positive indicating no urgency to replace it. Again no pressure tactics.

Three days after first meeting with Bob, the installation team of Greg and
Spencer completed the installation within the planned time frame.

A very professional, courteous and transparent team which delivered on their promise. I highly recommend Twintech.

by Private User on Twintech Heating and Cooling

Initial contact with sales resulted in an immediate response, which led to a timely installation. Both sales and installers were all very professional. I have no hesitation in recommending TWINTECH.

by Private User on Twintech Heating and Cooling

I had a great experience with TwinTech. The company offered a reasonable quote, and performed a quick and clean installation. The installer Greg was experienced, professional and courteous. He explained the services he performed and gave recommendations on maintain the new furnace.

The salesman Bob was honest
and professional and educated me on how to achieve optimal performance.

All communication from them was quick and they came the following day. I was pleased with the service and would recommend them.

by Lousan, Ajax on Twintech Heating and Cooling

From quote, to installation, to follow up, Twintech provided excellent service. I would highly recommended their services.

by John, Pickering on Twintech Heating and Cooling

I had a really great experience with these guys. The salesman Bob was clearly very knowledgeable about everything to do with heating and cooling a home, spent a lot of time with us going over the details of the job, never rushed us and came back after the install to make sure we were happy. The installation crew was excellent, they covered the floors all the way from outside down to the basement furnace room, kept the place clean, got the work done on time and weÂ’re very friendly. IÂ’ve got 15 years in the contracting/ construction industry and these guys are one of the most professional companyÂ’s IÂ’ve dealt with. Great company!

by Debra Robertson on Twintech Heating and Cooling

Had great service and clean-up was good. Was happy with my salesman. They were very friendly and helpful. I needed a new furnace as our was over 20 years old. The furnace and air-conditioner work great and they are very quiet. I am very pleased with the service and product I received.

by Private User on Twintech Heating and Cooling

Met with Dave for the sales process and he was great about explaining and going over everything to us. The install happened very quickly and the team were super professional and friendly. We are very happy with this company and their services and we definitely recommend them to others. Thankful my sister recommended them to me!

by Private User on Twintech Heating and Cooling

Reviews for Twintech were good, and they did not disappoint. After an initial visit to discuss the suitable AC unit for replacement, an installation date was available in just a couple of days, and everything was installed without a hitch. Highly recommended

by Private User on Twintech Heating and Cooling

Very pleased with the installation of our new furnace and A/C unit. From quotation stage to the completion of the job Twintech was very professional.
Thank you for a job well done.

by Darren, Pickering on Twintech Heating and Cooling

My old water heater quit on me. I called TwinTech. In less than 4 days, I had my new water heater installed and the old one taken away. The whole process was quick, easy, pleasant, and well done. This is the third time I've dealt with TwinTech and I've been satisfied each time.

See What Our Customers Are Saying:

by Robert Rogers on Twintech Heating and Cooling

Very pleased with the professional service that TwinTech Heating and Cooling provided in replacing my furnace. I got several quotes from different service providers. Their price was excellent and they explained the features very well. We are very glad we went with TwinTech and highly recommend their services.

by Robert Mizuno on Twintech Heating and Cooling

We were new homeowners in need of a second opinion. TwinTech Heating & Cooling were Amazing and professional. Very knowledgeable and great service all around. Recommend to anyone looking for honest and reliable services. Treated with respect and care. Thank you Greg, Mitch and Bob!

by Ruth on Twintech Heating and Cooling

TwinTech is an excellent and honest company! I called them for a second opinion after being told by another company that I needed to replace my furnace. Turns out this was not the case at all! I did not need a new furnace. TwinTech did not push to make an unnecessary sale and saved me from a huge expense. Bob and Mitch were extremely professional and above all honest! I definitely recommend TwinTech!

by Anna Chin on Twintech Heating and Cooling

Amazing experience with TwinTech Heating & Cooling! Their team was professional, knowledgeable, and efficient from start to finish. They installed my new furnace quickly and left everything spotless. The technicians took the time to explain everything and made sure I was comfortable with the system before they left. Great customer service and fair pricing. I highly recommend them for anyone needing HVAC services!

by Connor Agnew on Twintech Heating and Cooling

Great experience all around. Bob was sharp and easy to talk to, and Greg handled the installation perfectly. Would hire them again in a heartbeat.

Why Did My Heat Pump Shut Off On Its Own?

  • SUBMITTED BY:
  • TWINTECH HEATING & COOLING
  • - November 26, 2023

There could be several reasons why your heat pump shut off on its own. Some common reasons include: Thermostat Settings: Check your thermostat settings to ensure that the desired temperature is set correctly. If the temperature setti

Read More

Looking to buy a house and convert to heat pumps in New England What should I be looking for?

  • SUBMITTED BY:
  • TWINTECH HEATING & COOLING
  • - April 1, 2023

Apologies if there's a better sub to ask this. As in the title, I'm in the market for a house in the NE US, and I'd like to fully switch to heat pumps for heating and cooling once purchased. Is there anything specifically in the house I should be loo

Read More

Electricity Question For my Heat Pump

  • SUBMITTED BY:
  • TWINTECH HEATING & COOLING
  • - September 29, 2023

I have an old electric central heater that's consuming a LOT of electricity. Seems to be a D15 (60 amps). I have a 100 amps board for the house. I am looking for a central heat pump system with exterior and interior units and most instal

Read More

nest thermostat messed up my air conditioner?

  • SUBMITTED BY:
  • TWINTECH HEATING & COOLING
  • - September 3, 2023

A Nest thermostat, like other smart thermostats, should not inherently "mess up" your air conditioner if installed and configured correctly. In fact, these devices are designed to help improve the efficiency and control of your HVAC (hea

Read More